





































Flood protection
Flexible water barrier from Buitink – supplied by FabriQ™
Fast, robust and sustainable flood protection and water control
Buitink Technology has developed a flexible, collapsible water barrier that rolls out and automatically anchors itself to the ground when the water rises. The system requires no anchoring, electricity or tools – and can be used on grass, asphalt, gravel, slopes or rocky surfaces.
The barrier is 100% manufactured in Europe under strict quality standards – without prefabricated components from low-cost countries.
Advantages of Buitink Flexible Water Dam (BFW)
✅ Extremely quick assembly – no tools or machines required
✅ Self-anchoring – water pressure automatically anchors the system
✅ Lightweight and modular – easy to transport, move and connect in length
✅ Maintenance-free and reusable – hundreds of use cycles
✅ Chemical resistant and UV resistant - withstands harsh conditions
✅ Flexible in height and length - adapts to your needs
✅ Environmentally friendly and quiet in use – no motors, no emissions
✅ Cost-effective – low operating and maintenance costs
Areas of application
1. Flood protection
Protects cities, towns, industrial areas and infrastructure against flooding.
No electricity, no equipment and no digging – the system is rolled out and activated automatically when the water rises.
2. Flexible rubber dam
Perfect for draining lakes, rivers and ponds during inspection, maintenance or construction.
No interference with nature, no noise, no oil spills – the habitat remains intact.
3. Fire water reservoir
Quickly create a reservoir where there are natural water sources – in the mountains, forests, agriculture or cities.
A cost-effective alternative to water pipes, tanks and fixed infrastructure.
4. Collection of contaminated water
Collects and retains oil, foam or other contaminants floating on water.
Purified water is discharged via a bottom valve. Residues are collected and safely treated.
Technical performance
-
Temperature resistance: –30 to +70 °C
-
Resistant to most chemicals and aggressive media
-
No moving parts = no maintenance required
-
Can be repaired on site in case of damage
-
Requires only labor – no machinery or fuel
-
Compact storage – saves transportation costs and space
Examples of use:
-
Flood protection in urban environments
-
Closing of river sections for inspection
-
Temporary fire water for forest fire preparedness
-
Control of wastewater or chemical emissions at facilities
-
Safety measures at filling stations, industry and ports
A smarter alternative to rigid, expensive and cumbersome systems
Buitink Flexible Water Dam is a future-proof alternative to sandbags, concrete barriers and underground water systems. The solution gives you fast response , minimal operating costs and maximum operational flexibility .
FabriQ™ is the exclusive distributor of Buitink Technology's flexible dams in Scandinavia.
Contact us today for technical specifications, project customization, or a complete quote.
Sizes and types of flexible dam
Buitink Flexible Water Dam is available in various designs and sizes. We can also offer customized solutions.
The types in the table below are the standard sizes you can get away with in 95% of all cases.
Table specifications flexible water pond
BUITINK WATER BARRIER |
Barrier height |
Length of barrier |
Holes in pollution |
Standup sticks incl. |
Width ground surface |
Type | (cm) | (m) | (pcs) | (pcs) | (cm) |
BFW-35-10-NO-NO | 35 | 10 | NO | NO | 145 |
BFW-35-10-JA-JA | 35 | 10 | YES | YES | 145 |
BFW-35-10-NO-YES | 35 | 10 | NO | YES | 145 |
BFW-50-10-NO-NO | 50 | 10 | NO | NO | 212 |
BFW-50-10-JA-JA | 50 | 10 | YES | YES | 212 |
BFW-50-10-NO-YES | 50 | 10 | NO | YES | 212 |
BFW-70-10-NO-NO | 70 | 10 | NO | NO | 275 |
BFW-70-10-JA-JA | 70 | 10 | YES | YES | 275 |
BFW-70-10-NO-YES | 70 | 10 | YES | YES | 275 |
PACKAGE | Length | Width | Height | Weight |
Type | (cm) | (cm) | (cm) | (kg) |
BFW-35-10-NO-NO | 106 | 42 | 33 | 36 |
BFW-35-10-JA-JA | 106 | 42 | 33 | 36 |
BFW-35-10-NO-YES | 106 | 42 | 33 | 36 |
BFW-50-10-NO-NO | 90 | 50 | 43 | 61 |
BFW-50-10-JA-JA | 90 | 50 | 43 | 62 |
BFW-50-10-NO-YES | 90 | 50 | 43 | 61 |
BFW-70-10-NO-NO | 120 | 50 | 35 | 58 |
BFW-70-10-JA-JA | 120 | 50 | 35 | 58 |
BFW-70-10-NO-YES | 120 | 50 | 35 | 58 |

Pris oppgis ved forespørsel